Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Phys Med Biol ; 58(8): 2657-74, 2013 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-23552770

RESUMO

Respiratory motion can blur the tomographic reconstruction of positron emission tomography or single-photon emission computed tomography (SPECT) images, which subsequently impair quantitative measurements, e.g. in the upper abdomen area. Respiratory signal phase-based gated reconstruction addresses this problem, but deteriorates the signal-to-noise ratio (SNR) and other intensity-based quality measures. This paper proposes a 3D reconstruction method dedicated to micro-SPECT imaging of mice. From a 4D acquisition, the phase images exhibiting motion are identified and the associated list-mode data are discarded, which enables the reconstruction of a 3D image without respiratory artefacts. The proposed method allows a motion-free reconstruction exhibiting both satisfactory count statistics and accuracy of measures. With respect to standard 3D reconstruction (non-gated 3D reconstruction) without breathing motion correction, an increase of 14.6% of the mean standardized uptake value has been observed, while, with respect to a gated 4D reconstruction, up to 60% less noise and an increase of up to 124% of the SNR have been demonstrated.


Assuntos
Imageamento Tridimensional/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Feminino , Camundongos , Neoplasias Peritoneais/diagnóstico por imagem , Neoplasias Peritoneais/fisiopatologia , Ratos , Respiração , Estudos Retrospectivos
2.
Eur J Nucl Med Mol Imaging ; 35(9): 1602-7, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18491090

RESUMO

PURPOSE: The aim of this study was to investigate the influence of a computer-based decision support system (DSS) on performance and inter-observer variability of interpretations regarding ischaemia and infarction in myocardial perfusion scintigraphy (MPS). METHODS: Seven physicians independently interpreted 97 MPS studies, first without and then with the advice of a DSS. Four physicians had long experience and three had limited experience in the interpretation of MPS. Each study was interpreted regarding myocardial ischaemia and infarction in five myocardial regions. The patients had undergone a gated MPS using a 2-day stress/gated rest (99m)Tc sestamibi protocol. The gold standard used was the interpretations made by one experienced nuclear medicine specialist on the basis of all available clinical and image information. RESULTS: The sensitivity for ischaemia of the seven readers increased from 81% without the DSS to 86% with the DSS (p = 0.01). The increase in sensitivity was higher for the three inexperienced physicians (9%) than for the four experienced physicians (2%). There was no significant change in specificity between the interpretations. The interpretations of ischaemia made with the advice of the DSS showed less inter-observer variability than those made without advice. CONCLUSION: This study shows that a DSS can improve performance and reduces the inter-observer variability of interpretations in myocardial perfusion imaging. Both experienced and, especially, inexperienced physicians can improve their interpretation with the advice from such a system.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Coração/diagnóstico por imagem , Miocárdio/patologia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Feminino , Humanos , Masculino , Infarto do Miocárdio/diagnóstico por imagem , Redes Neurais de Computação , Variações Dependentes do Observador , Perfusão , Cintilografia
3.
Q J Nucl Med Mol Imaging ; 51(1): 61-6, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17372574

RESUMO

AIM: Stem cell homing to injured tissue is necessary for local tissue repair. But homing of stem cells in chronic ischemic heart disease (CIHD) is poorly understood. This study investigated homing of peripheral blood stem cells (PBSC) expressing the CD133 antigen. After intracoronary injection. The cells were (111)In labeled for in vivo visualization. METHODS: PBSC were mobilized with granulocyte-colony stimulating factor and collected by apheresis on d-1. On d0, CD133+ cells were enriched up to a median purity of 89% (range: 79-97%) with an immunomagnetic separation device (CliniMACS, Miltenyi). A fraction of the cells was radiolabeled with [(111)In]oxine in 0.1 M TRIS at pH 7.4 for 45-60 min. Cell viability after labeling was assessed using trypan-blue. The cells were injected at a radioactive concentration of 0.9 MBq/10(6) cells into the target open coronary vessel through a balloon catheter. During balloon inflation [(99m)Tc]sestamibi was injected intravenously to identify the myocardium and the target vascular territory. Eight patients (mean age: 53 years; range: 50-72 years) with stable CIHD and reduced left ventricular function (NYHA class I-II) after acute myocardial infarction (>12 months) were studied. After a first cohort of 3 patients received an injectate of 5-10 x 10(6) cells, our final protocol was applied in 5 patients in whom an average of 34.4 x 10(6) (range: 18.6-49.4) CD133+ cells was injected. Whole body and single photon emission computed tomography (SPECT) scans were acquired at different time points after injection (energy windows set at 140, 171 and 245 keV). Residual activity in the heart was assessed by drawing a region of interest around the heart on the anterior whole body views. RESULTS: Mean labeling efficiency of [111In]oxine labeling was 51.2% and cell viability after labeling averaged 88%. In the 5 patients receiving the higher amount of labeled cells, a clear (111)In-signal was observed in the heart region up to 3 days after administration. Fused [(99m)Tc]sestamibi/(111)In SPECT images demonstrated that the regional distribution of the transplanted cells within the target zone, as delineated by the flow tracer, remained unchanged over time. A biodistribution study in 2 patients showed a residual activity in the heart, liver and spleen of 6.9-8%, 23.1-26.8%, 3.1-3.7%, respectively, after 1-2 h and 2.3-3.2% 23.8-28.3%, 3.5-3.8%, respectively, after 12 h (decay corrected and expressed as a percentage of total body initial activity). No adverse events were observed during the procedure and up to 3 months follow-up. CONCLUSIONS: Radiolabeling with [(111)In]oxine is a suitable method for follow-up of cell distribution during the first days after transplantation. A significant amount of CD133+ PBSC home to the heart after intracoronary injection in patients with CIHD. The results of this study are useful for the design of trials that evaluate the tissue repair potential of CD133+ PBSC in the setting of CIHD.


Assuntos
Anticorpos Monoclonais , Antígenos CD/imunologia , Glicoproteínas/imunologia , Transplante de Células-Tronco Hematopoéticas/métodos , Células-Tronco Hematopoéticas/diagnóstico por imagem , Radioisótopos de Índio , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/cirurgia , Peptídeos/imunologia , Antígeno AC133 , Doença Crônica , Feminino , Humanos , Masculino , Isquemia Miocárdica/patologia , Cintilografia , Compostos Radiofarmacêuticos
4.
Eur J Nucl Med Mol Imaging ; 32(11): 1317-23, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16133394

RESUMO

PURPOSE: In subjects without underlying cardiac disease dobutamine is known to enhance systolic LV function and LV relaxation. As end-systolic (ES) and end-diastolic (ED) volumes (V) can be derived from gated SPECT we intent to study these volumes and their response to dobutamine in order to have a better understanding of the mechanism by which stroke volume (SV) increases during dobutamine infusion. We intent to do this in normal controls and in young diabetic subjects. METHODS: After injection of sestamibi, serial gated SPECT were obtained at baseline, and during low doses of dobutamine infusion in 12 asymptomatic type I diabetic patients, and in 12 age matched controls. LV EDV, ESV, SV and EF were calculated with the QGS program. RESULTS: Gated SPECT showed comparable LV EF and SV in both groups at rest. There was a significant increase in LVEF and SV during dobutamine infusion but in the diabetic patients the increase in SV was due to a decrease in ESV from 25+/-5 to 20+/-6 ml/m2 (p=0.002) and no change in EDV. In normal controls, the increase in EF was due to an increase in EDV from 69+/-10 to 73+/-12 ml/m2 (p=0.002) with no significant change in ESV. CONCLUSION: These data confirm the presence of subclinical abnormalities of diastolic function in asymptomatic type I diabetic patients and show differences in adaptation to inotropic stimulation in order to preserve the increase in stroke volume and LV ejection fraction.


Assuntos
Diabetes Mellitus Tipo 1/diagnóstico por imagem , Dobutamina/administração & dosagem , Imagem do Acúmulo Cardíaco de Comporta/métodos , Volume Sistólico/efeitos dos fármacos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/tratamento farmacológico , Adulto , Cardiotônicos/administração & dosagem , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/tratamento farmacológico , Relação Dose-Resposta a Droga , Humanos , Masculino , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia
5.
Nucl Med Commun ; 23(2): 171-4, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11891472

RESUMO

The aim of this study was to assess the influence of the physiological changes of gastric emptying on the simplified 14C-urea breath test. Thirty patients performed the test in fasting conditions. Patients were orally administered 0.074 mega Bq of 14C-urea, mixed with 0.0185 mega Bq of 99mTc-S colloids in 25 ml water. A breath sample was taken before and 10 min after intake of the tracers and followed by a 2 min planar anterior scintigraphic image of the abdomen to measure gastric activity. Gastric emptying was estimated by dividing the residual gastric activity at 10 min by the total activity in the abdomen. The procedure was performed twice for each patient after a 24 h interval. The repeatability of both the gastric emptying test and the urea breath test was assessed by the method described by Bland and Altman. The coefficient of repeatability of the urea breath test was 1.18 for a confidence interval of 95%. The coefficient of repeatability of gastric emptying was 27.4. There was no significant correlation (r= 0.08) between the plot of the individual modifications of urea breath test and residual gastric activity in two successive tests. It is concluded that the physiological changes of gastric emptying do not influence the results obtained by the simplified, single-sample 14C-urea breath test.


Assuntos
Testes Respiratórios/métodos , Isótopos de Carbono , Esvaziamento Gástrico/fisiologia , Ureia , Reações Falso-Negativas , Seguimentos , Infecções por Helicobacter/diagnóstico , Helicobacter pylori , Humanos , Sensibilidade e Especificidade , Água/metabolismo
6.
J Nucl Cardiol ; 8(4): 466-71, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11481569

RESUMO

BACKGROUND: Two different algorithms, which are fast and automatic and which operate in 3-dimensional space, were compared in the same group of patients to compute left ventricular ejection fraction (LVEF) and volumes from gated blood pool tomography. One method, developed at Cedars-Sinai Medical Center (CS), was dependent on surface detection, whereas the other method, developed at the Free University of Brussels (UB), used image segmentation. METHODS AND RESULTS: Gated blood pool tomograms were acquired in 92 consecutive patients after injection of 740 MBq of technetium 99m-labeled human serum albumin. After reconstruction and reorientation according to the left ventricular long axis, LVEF and left ventricular volumes were measured with the CS and UB algorithms. Measurements of LVEF were validated against planar radionuclide angiocardiography (PRNA) results. The success rates of the algorithms were 87% for CS and 97% for UB. Agreement between LVEF measured with CS and UB (LVEF(CS) = 0.91. LVEF(UB) - 0.85; r = 0.87) and between LVEF measured with CS and PRNA (LVEF(CS) = 1.04. LVEF(PRNA) - 4.75; r = 0.80) and UB and PRNA (LVEF(UB) = 0.98. LVEF(PRNA) + 4.42; r = 0.82) was good. For left ventricular volumes, linear regression analysis showed good correlation between both methods with regard to end-diastolic volumes (r = 0.81) and end-systolic volumes (r = 0.91). On average, end-diastolic volumes were similar and end-systolic volumes were slightly higher with CS than with UB. Consequently, significantly lower LVEFs were observed with CS than with UB. CONCLUSIONS: Good correlation was observed between CS and UB for both left ventricular volumes and ejection fraction. In addition, measurements of LVEF obtained with both algorithms correlated fairly well with those obtained from conventional PRNA over a wide range of values.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta , Imageamento Tridimensional , Volume Sistólico , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Angiografia Cintilográfica
7.
J Nucl Med ; 42(3): 401-7, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11337514

RESUMO

UNLABELLED: The aim of this study was to develop and validate a new algorithm to automatically compute left ventricular ejection fraction (LVEF) from gated blood-pool tomography (GBPT). The results were compared with those of conventional planar radionuclide angiocardiography (PRNA). METHODS: Fifty-three consecutive patients received an injection of 740 MBq (99m)Tc-labeled human serum albumin. PRNA and GBPT were performed consecutively in a random sequence. PRNA served as the reference, and GBPT images were processed using a new edge detection algorithm. The algorithm is fast (<45 s), fully automatic, and works in three-dimensional space. The method includes identification of the valve plane and the septum. The left ventricular cavity at end-diastole is delineated by segmentation using an iterative threshold technique. An optimal threshold is reached when the corresponding isocontour best fits the first derivative of the end-diastolic count distribution in three dimensions. This optimal threshold is then applied to delineate the left ventricular cavity on the other time bins. The data are corrected for the partial-volume effect. Left ventricular volumes are determined using a geometry-based method and are used to calculate the ejection fraction. RESULTS: The success rate of the new algorithm was 94%. LVEFs calculated from GBPT agreed well with those calculated from PRNA (r = 0.78; GBPT = 0.94 PRNA + 6.33). The systematic error was 2.8%, and the random error was 8.8%. Excellent inter- and intraobserver reproducibility was found, with average differences of 1.1% +/- 4.6% and 1.1% +/- 5.0%, respectively, between the two measurements. CONCLUSION: This new algorithm provides a fast, automated, and objective method to calculate LVEF from GBPT.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes
8.
J Gastroenterol ; 36(3): 187-9, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11291882

RESUMO

This study was performed to assess the impact of precise timing and the repeatability of the simplified 10-min 14C-urea breath test. Thirty-three patients underwent a 14C-urea breath test at 10 and 12 min (test I) and after 24 h (test II). The paired t-test was applied to assess differences between two successive measurements at 10 and 12 min, and the method of Bland and Altman was used to evaluate the repeatability of the test. Only test I (P = 0.004) showed a significant difference between two successive measurements at 10 and 12 min. The coefficients of repeatability at 10 and 12 min were 1.54 and 1.48, respectively. No bias was found. From this study, we can conclude that breath collections, delayed by 2 min (20% error), have no impact on the clinical interpretation of the results. The repeatability of the simplified 10-min 14C-urea breath test is sufficient for clinical use.


Assuntos
Testes Respiratórios/métodos , Radioisótopos de Carbono , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Tempo , Ureia
9.
Dig Liver Dis ; 33(1): 30-5, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11303972

RESUMO

BACKGROUND: The best timing and the best cut-off level of the 13C-urea breath test have not yet been well established. AIMS: To evaluate the cut-off value and the influence of medication on the 13C-urea breath test as measured by infrared spectrometry. METHODS: A series of 223 patients, sent for endoscopy performed 13C-urea breath test in fasting conditions with 75 mg of 13C-urea and 20 ml of citric acid. Breath samples were collected before and then 10, 20, 25 and 30 minutes after ingestion. As gold standard, histological examination of gastric biopsies was used. A questionnaire was completed concerning the intake of medication, likely to influence the test, in the 2 months preceding the test. Sensitivity, specificity, positive predictive value and negative predictive value at 10, 20, 25 and 30 minutes at different cut-off values (3, 3. 5, 4, 4. 5, 5.0 0/00 DOB] were calculated. RESULTS: A total of 182 patients did not take medication. There was no significant difference between the different cut-off levels at different times. Compared with the group of 41 patients who did take medication, likely to influence the test, the differences were significant (Fisher exact test). CONCLUSION: There was no significant difference between the different cut-off values. A 10-minute test with a cut-off level between 4 and 5% delta over baseline (sensitivity: 100%, specificity: 95%) is, therefore, proposed. To avoid false negative results due to unknown intake of medication, every patient submitted to the 13C-urea breath test should fill out a questionnaire.


Assuntos
Testes Respiratórios , Gastrite/diagnóstico , Infecções por Helicobacter/diagnóstico , Helicobacter pylori , Espectrofotometria Infravermelho , Ureia , Radioisótopos de Carbono , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
10.
Helicobacter ; 5(2): 104-8, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10849060

RESUMO

BACKGROUND: The 13C urea breath test (13C-UBT) is the most convenient method for diagnosing Helicobacter pylori infection noninvasively. Nondispersive isotope-selective infrared spectrometry (NDIRS) is an inexpensive and easy alternative to mass spectrometry. The objective of this study was to evaluate: (1) the reproducibility of the 13C-UBT as performed by using the NDIRS method; (2) the repeatability of bags analysis and the impact of delayed analysis; and (3) the need for fasting status for the 13C-UBT. METHODS: The 13C-UBT was performed with 75 mg urea labeled with 13C, with breath samples collected at times 0 and 30 minutes. Results are expressed as delta over baseline (0/00). Fifty-three patients underwent two successive 13C-UBTs with an interval of 48 to 72 hours. The 106 collected bags were randomly reanalyzed immediately or 72 hours later. In 26 volunteer subjects, the 13C-UBT was performed both in a fasting condition and after a nonstandardized meal. The reproducibility was assessed by the method of Bland and Altman. RESULTS: The mean of difference between two successive tests was 0. 14 0/00 (standard deviation, 0.90), and the coefficient of repeatability was 1.80 (confidence interval, 95%). The difference between two successive analyses was always less than 2.2% of the initial value. The coefficient of variation between two successive tests for the influence of a meal was 11.24. CONCLUSION: The 13C-UBT as performed by using NDIRS is reproducible, analyses can be delayed up to 72 hours, and the test must be performed in fasting conditions.


Assuntos
Testes Respiratórios/métodos , Infecções por Helicobacter/diagnóstico , Helicobacter pylori , Espectrofotometria Infravermelho/métodos , Ureia , Isótopos de Carbono , Jejum/fisiologia , Feminino , Infecções por Helicobacter/fisiopatologia , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Eur J Nucl Med ; 27(4): 413-8, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10805114

RESUMO

Perfusion scintigraphy provides important information regarding the presence of viable tissue after myocardial infarction. Defects of moderate severity, however, may represent viable myocardium, necrotic tissue or a mixture of both. In this study the presence or absence of inotropic response in the infarcted area was assessed by low-dose dobutamine tetrofosmin gated single-photon emission tomography (LDD gated SPET). Results were compared with those obtained with stress echocardiography (SE). Twenty-five patients with acute myocardial infarction were studied. Gated SPET myocardial perfusion imaging was performed 60 min after the injection of technetium-99m tetrofosmin (925 MBq) at rest using a triple-headed camera equipped with focussing collimators (Cardiofocal). Two consecutive acquisitions were performed according to a "fast" gated SPET protocol (3x20 stops, 9 s/stop, 64x64 pixel matrix, zoom 1.23) with the subjects remaining in the same position. The first acquisition was obtained at rest; the second acquisition was obtained under infusion of 10 microg kg(-1) min(-1) dobutamine. The severity of regional dysfunction, wall thickening severity (WTsev), was assessed and quantified using a method based on circumferential profile analysis. SE was performed at rest and during infusion of 5 and 10 microg kg(-1) min(-1) dobutamine. Two patients could not be analysed because of disturbing gastro-intestinal activity on the perfusion study. Under dobutamine 11 patients presented a significant change in WTsev (three showed normalisation, five an improvement and three a deterioration), while in 12 patients the WTsev score remained unchanged. The overall concordance between LDD gated SPET and SE was 83%. In patients with perfusion defects of moderate severity the concordance was 90% (9/10). It may be concluded that functional changes in infarcted areas induced by dobutamine can be detected with gated SPET. Good agreement was observed between LDD gated SPET and SE for the identification of inotropic reserve in infarcted areas.


Assuntos
Cardiotônicos , Dobutamina , Ecocardiografia , Infarto do Miocárdio/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Cardiotônicos/administração & dosagem , Dobutamina/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Compostos Radiofarmacêuticos , Volume Sistólico , Tecnécio
12.
Eur J Nucl Med ; 27(4): 419-24, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10805115

RESUMO

Viability studies are often performed in patients receiving beta-blocking agents. However, the intake of beta-blocking agents could influence the identification of viable myocardium when low-dose dobutamine is used to demonstrate inotropic reserve. The aim of this study was to quantify the effect of beta-blockade on global and regional left ventricular function in healthy volunteers using low-dose dobutamine gated single-photon emission tomographic (SPET) myocardial perfusion scintigraphy. Ten subjects were studied once "on" and once "off" beta-blocker therapy (metoprolol succinate, 100 mg day(-1)). On each occasion four consecutive gated SPET acquisitions (of 7 min duration) were recorded after injection of 925 MBq technetium-99m tetrofosmin on a triple-headed camera equipped with focussing (Cardiofocal) collimators. Acquisitions were made at rest (baseline 1 and 2) and 5 min after the beginning of the infusion of 5 and 10 microg kg(-1) min(-1) dobutamine. Wall thickening (WT) was quantified using a method based on circumferential profile analysis. Left ventricular ejection fraction (LVEF) was obtained using the Cedars-Sinai algorithm. Blood pressure (BP) and heart rate (HR) were recorded at the end of each acquisition. At baseline LVEF, WT and systolic BP values under beta-blockade were not significantly different from those obtained in the non-beta-blocked state. The mean HR and diastolic BP at baseline were lower under beta-blockade. Dobutamine administration (at 5 and 10 microg kg(-1) min(-1)) induced a significant increase in WT, LVEF and systolic BP in all subjects both on and off beta-blockade. The increases in WT, LVEF and systolic BP in the beta-blocked state were less pronounced but not significantly different. HR increased significantly at 10 microg kg(-1) min(-1) dobutamine without beta-blocker administration, while no increase in HR was observed in the beta-blocked state. Beta-blocker therapy in healthy subjects attenuates the inotropic and chronotropic myocardial response to low-dose dobutamine. At doses of 5 and 10 microg kg(-1) min(-1) dobutamine, however, significant increases in global and regional left ventricular function can still be measured using consecutive gated SPET myocardial perfusion scintigraphy acquisitions even under beta-blocker therapy.


Assuntos
Agonistas Adrenérgicos beta/farmacologia , Antagonistas Adrenérgicos beta/farmacologia , Dobutamina/farmacologia , Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Função Ventricular Esquerda/efeitos dos fármacos , Adulto , Pressão Sanguínea/efeitos dos fármacos , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Metoprolol/farmacologia , Contração Miocárdica/efeitos dos fármacos , Compostos Organofosforados , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Volume Sistólico/efeitos dos fármacos , Função Ventricular Esquerda/fisiologia
13.
J Nucl Cardiol ; 7(1): 29-36, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10698232

RESUMO

BACKGROUND: Tetrofosmin gated single photon emission computed tomography (SPECT) allows simultaneous assessment of regional myocardial perfusion, global and regional left ventricular function, and function at rest and during pharmacologic intervention. SPECT with fatty acid analogues, such as beta-methyl-iodophenyl-pentadecanoic acid (BMIPP), can be used to monitor metabolic changes induced by myocardial ischemia. In this work, the results of both studies obtained in patients with recent myocardial infarction are integrated. METHODS: Twenty patients underwent tetrofosmin and BMIPP scintigraphy with a 3-head camera. Two consecutive tetrofosmin gated SPECT acquisitions were performed 60 minutes after administration of technetium-99m tetrofosmin (925 MBq) at rest (3x20 stops of 9 s; matrix 64x64 over 360 degrees . One acquisition was made at rest, and the second was made during dobutamine infusion (10 microg/kg/min). Regional functional abnormalities were quantified and expressed as wall thickening severity (WTsev) in arbitrary units. Left ventricular ejection fraction and volumes were assessed with the Cedars Sinai algorithm. BMIPP imaging started 20 minutes after iodine 123-BMIPP (150 MBq) administration at rest (3x32 stops of 60 s; matrix 64x64 over 360 degrees; medium energy collimators). Tracer uptake was scored according to a 25-segment model. RESULTS: Sixteen of 18 patients had regional functional abnormalities at baseline (average WTsev 13.7 units). The WTsev score at baseline correlated well with the degree of residual perfusion. During dobutamine infusion, WTsev did not change (from 23.4 to 23.6 units) in 5 patients; it decreased (from 16.1 to 5.9 units) in 11 patients; and it increased (from 13.0 to 22.3 units) in 3 patients. An increase or decrease in WTsev during dobutamine infusion was associated with the presence of a considerable amount of BMIPP mismatched myocardium, whereas no change in WTsev was preferentially associated with a BMIPP matched pattern and perfusion defects with a higher severity score. CONCLUSION: Immediately after infarction, the severity of regional dysfunction at rest correlated well with the perfusion defect severity. Improvement in regional function during dobutamine administration is associated with less severe perfusion defects and a considerable amount of BMIPP mismatched myocardium, both suggesting viability.


Assuntos
Dobutamina , Ácidos Graxos , Radioisótopos do Iodo , Iodobenzenos , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio/metabolismo , Compostos Organofosforados , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Circulação Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Infarto do Miocárdio/metabolismo , Infarto do Miocárdio/fisiopatologia , Volume Sistólico , Função Ventricular Esquerda
14.
Eur J Nucl Med ; 27(1): 33-40, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10654144

RESUMO

We have evaluated the biodistribution and metabolism of iodine-123-15-(p-iodophenyl)-3-R,S-methyl pentadecanoic acid (BMIPP) in the presence of increased lactate levels induced by short-term heavy exercise. Five healthy male subjects received 159 MBq (+/- 13 MBq) 123I-BMIPP at rest and a week later after they performed a maximal exercise test using a bicycle ergometer. Planar and tomographic images were obtained with a dual-head gamma camera up to 4 h after administration of the tracer. Multiple blood samples were taken at different time points for blood clearance, substrate concentration measurements and for HPLC analysis of metabolites. The exercise test did not alter plasma glucose and non-esterified fatty acid concentrations, but blood lactate increased from 1.12 mmol/l at rest to 9.26 mmol/l with maximal exercise. After exercise, BMIPP showed a significantly faster plasma clearance than at rest and the production of PIPA, the end metabolite of BMIPP oxidation, was reduced. Activity in the heart was similar after exercise and at rest on planar images 15 min after injection (4.83 +/- 0.50% ID vs 4.80 +/- 0.43% ID, P = NS), although the myocardium-to-cavity activity ratio, as determined on the SPET images 20 min after tracer injection, was slightly increased after the exercise test (4.20 +/- 0.63 vs 3.78 +/- 1.34 at rest, P = NS). Significantly increased activity was observed in a leg muscle region of interest after exercise (4.98 +/- 0.50% ID vs 3.93 +/- 0.44% ID at rest, P = 0.02). Between early and late images, tracer washout from the myocardium increased from 20.72% at rest to 36.72% after exercise (P < 0.05), but was unchanged for liver and leg muscles. The metabolic and physiological alterations induced by exercise do not degrade image quality of BMIPP scintigraphy. On the contrary, exercise-induced hyperlactatemia seems to enhance myocardium-to-cavity activity ratios on SPET images, although this effect does not reach statistical significance in this small group of normal subjects. These findings further support the robustness of BMIPP SPET in varied metabolic environments.


Assuntos
Ácidos Graxos/farmacocinética , Radioisótopos do Iodo , Iodobenzenos/farmacocinética , Ácido Láctico/sangue , Adulto , Cromatografia Líquida de Alta Pressão , Teste de Esforço , Humanos , Masculino , Distribuição Tecidual , Tomografia Computadorizada de Emissão de Fóton Único
15.
Eur J Nucl Med ; 27(2): 140-6, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10755718

RESUMO

Pinhole single-photon emission tomography (SPET) has been proposed to improve the trade-off between sensitivity and resolution for small organs located in close proximity to the pinhole aperture. This technique is hampered by artefacts in the non-central slices. These artefacts are caused by truncation and by the fact that the pinhole SPET data collected in a circular orbit do not contain sufficient information for exact reconstruction. The ordered subsets expectation maximization (OS-EM) algorithm is a potential solution to these problems. In this study a three-dimensional OS-EM algorithm was implemented for data acquired on a single-head gamma camera equipped with a pinhole collimator (PH OS-EM). The aim of this study was to compare the PH OS-EM algorithm with the filtered back-projection algorithm of Feldkamp, Davis and Kress (FDK) and with the conventional parallel-hole geometry as a whole, using a line source phantom, Picker's thyroid phantom and a phantom mimicking the human cervical column. Correction for the angular dependency of the sensitivity in the pinhole geometry was based on a uniform flood acquisition. The projection data were shifted according to the measured centre of rotation. No correction was made for attenuation, scatter or distance-dependent camera resolution. The resolution measured with the line source phantom showed a significant improvement with PH OS-EM as compared with FDK, especially in the axial direction. Using Picker's thyroid phantom, one iteration with eight subsets was sufficient to obtain images with similar noise levels in uniform regions of interest to those obtained with the FDK algorithm. With these parameters the reconstruction time was 2.5 times longer than for the FDK method. Furthermore, there was a reduction in the artefacts caused by the circular orbit SPET acquisition. The images obtained from the phantom mimicking the human cervical column indicated that the improvement in image quality with PH OS-EM is relevant for future clinical use and that the improvements obtained using the OS-EM algorithm are more significant for the pinhole geometry than for the conventional parallel-hole geometry. We conclude that PH OS-EM is a practical and promising alternative for pinhole SPET reconstruction.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único , Artefatos , Vértebras Cervicais/diagnóstico por imagem , Humanos , Glândula Tireoide/diagnóstico por imagem , Fatores de Tempo , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/métodos
16.
Eur J Nucl Med ; 26(10): 1298-303, 1999 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-10541828

RESUMO

Electrocardiography gated single-photon emission tomography (gated SPET) allows the assessment of regional perfusion and function simultaneously and in full spatial congruency. In this study changes in global and regional left ventricular function in response to dobutamine infusion were assessed in ten healthy volunteers using sequential gated SPET myocardial perfusion acquisitions. Four consecutive gated SPET images were recorded 60 min after injection of 925 MBq technetium-99m tetrofosmin on a three-head camera equipped with focussing collimators. Two acquisitions were made at rest (baseline 1 and 2), and the third and fourth acquisitions were started 5 min after the beginning of the infusion of 5 and 10 microg kg(-1) min(-1) dobutamine, respectively. Systolic wall thickening (WT) was quantified using a method based on circumferential profile analysis. Left ventricular ejection fraction (LVEF) and volumes were calculated automatically using the Cedars-Sinai program. Nine of the ten subjects presented a definite increase in WT during dobutamine infusion. WT increased on average from 46%+/-14% at baseline to 71%+/-23% (range: 37%-106%; P<0.05) during 5 microg kg(-1) min(-1) dobutamine infusion and to 85%+/-25% (range: 62%-123%; P<0.05 with respect to WT at 5 microg kg(-1) min(-1)) during 10 microg kg(-1) min(-1) dobutamine infusion. Apical segments showed the largest WT at baseline. The average WT response to dobutamine was similar for all parts of the myocardium. It is concluded that changes in WT induced by infusion of low-dose dobutamine can be assessed by sequential gated SPET myocardial perfusion studies. The "stress gated SPET" protocol proposed in this study might be helpful to distinguish viable from scar tissue in patients with coronary artery disease, by demonstrating a preserved inotropic response in hypoperfused myocardium.


Assuntos
Agonistas Adrenérgicos beta/farmacologia , Circulação Coronária/efeitos dos fármacos , Dobutamina/farmacologia , Coração/diagnóstico por imagem , Função Ventricular Esquerda/efeitos dos fármacos , Adulto , Eletrocardiografia/efeitos dos fármacos , Ventrículos do Coração/diagnóstico por imagem , Hemodinâmica/efeitos dos fármacos , Humanos , Masculino , Modelos Anatômicos , Perfusão , Volume Sistólico/efeitos dos fármacos , Tomografia Computadorizada de Emissão de Fóton Único
17.
J Nucl Med ; 40(9): 1468-76, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10492367

RESUMO

UNLABELLED: Mismatching between beta-methyl-p-iodophenyl-pentadecanoic acid (BMIPP) and perfusion accurately predicts functional outcome after acute myocardial infarction. The current investigation was aimed at evaluating the value of this method to predict the evolution of global function according to the applied treatment in patients with chronic ischemic heart disease. METHODS: Twenty patients with infarction and chronic left ventricular dysfunction were studied (median infarction age 12 wk, range 2 wk-15 y). Radionuclide angiography, two-dimensional echocardiography and BMIPP and gated sestamibi scintigraphy were performed with the patient at rest before and >6 mo after treatment (revascularization in 13 patients and conservative therapy in 7 patients). In 7 patients, radionuclide angiography was repeated after 1 y. RESULTS: On a patient basis, mismatching with BMIPP less than sestamibi was noted in 15 patients at baseline. Of these 15 patients, 11 had significant functional improvement at follow-up versus only 1 of the 5 patients with a matched decreased uptake. Hence, the combined sestamibi/BMIPP was 73% positive and 80% negative in predicting functional outcome, with a global accuracy of 75%. On a segmental basis, using an optimal threshold of uptake defined by receiver operating characteristic curve analysis, sestamibi was only 63% accurate in predicting regional outcome. Adding BMIPP improved the accuracy to 80% (P = 0.001). At follow-up, significant mismatching was still noted in 7 patients in the revascularized group and 1 in the medically treated group. The mismatch was associated with a further increase in ejection fraction at 1-y follow-up in only the revascularized group. CONCLUSION: In patients with chronic left ventricular dysfunction after infarction, a mismatching with BMIPP less than sestamibi reliably identifies jeopardized but viable myocardium and predicts functional recovery with an accuracy similar to that reported in the acute and subacute phases of the infarction.


Assuntos
Ácidos Graxos , Radioisótopos do Iodo , Iodobenzenos , Infarto do Miocárdio/complicações , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Doença Crônica , Ecocardiografia , Feminino , Seguimentos , Imagem do Acúmulo Cardíaco de Comporta , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Infarto do Miocárdio/terapia , Revascularização Miocárdica , Valor Preditivo dos Testes , Curva ROC , Angiografia Cintilográfica , Recuperação de Função Fisiológica , Sensibilidade e Especificidade , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
18.
Int J Card Imaging ; 15(1): 27-34, 1999 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10453400

RESUMO

Assessment of myocardial viability is an important clinical issue for patient management during the acute and chronic stages of myocardial infarction. BMIPP (15-(p-iodophenyl)-3-(R,S)-methyl pentadecanoic acid) is a free fatty acid analogue which is trapped in the myocardium, thus permitting for metabolic imaging with single photon emission computerized tomography (SPECT). Less BMIPP than flow tracers that may be observed in the areas of infarction, may reflect the metabolic shift from fatty acid to glucose utilization in ischaemic myocardium. In this sense, the combined imaging of BMIPP and a flow tracer with SPECT may provide similar and important information as fluoro-18 deoxyglucose (FDG) and positron emission tomography (PET) regarding the assessment of myocardial viability. The purpose of this article is to review the clinical impact of BMIPP in patients with acute and with chronic left ventricular dysfunction for the identification of jeopardized but viable myocardium and the prediction of the functional outcome.


Assuntos
Ácidos Graxos , Coração/diagnóstico por imagem , Radioisótopos do Iodo , Iodobenzenos , Tomografia Computadorizada de Emissão de Fóton Único , Disfunção Ventricular Esquerda/diagnóstico por imagem , Animais , Humanos , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão
19.
Eur J Nucl Med ; 26(6): 655-8, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10369952

RESUMO

Using iodine-123 labelled radiotracers, the presence of 2.5% high-energy photons causes image deterioration due to increased scatter. To investigate the influence of these photons on image quality, we measured the spectrum of 123I with a medium-energy (ME), a low-energy all-purpose (LEAP) and a low-energy high-resolution (LEHR) collimator. Even in air, using low-energy collimators a high baseline activity was observed over the total energy detection range of the gamma camera. The 159-keV photopeak to scatter activity ratio fell from 5.9 for ME to 3.6 and 2.9 for LE collimators. Acquisition of images with LEHR collimators with energy windows set at 159 keV and 500 keV demonstrated that the 159-keV LEHR image is a combination of the ME image of the object and of the LEHR 500-keV image. Because of their important septal penetration and greater geometric detection efficiency compared with the 159-keV photons of 123I, the contribution of high-energy photons is dependent on the source-detector distance. For a small source placed in air, the scatter to photopeak activities varied from 17.4% at 80 cm to 37.8% at 5 cm distance from an LEHR collimator. Considering only the scatter problem, ME collimators are the best choice for 123I studies. When using LE collimators for high-resolution tomography with 123I-labelled compounds, scatter contribution from high-energy photons has to be corrected for quantitative analysis or when dual-isotope studies are performed, whether or not these studies are acquired simultaneously.


Assuntos
Câmaras gama , Radioisótopos do Iodo , Compostos Radiofarmacêuticos , Humanos , Imagens de Fantasmas , Espalhamento de Radiação
20.
Nucl Med Commun ; 20(4): 335-43, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10319353

RESUMO

We present a modified (non-segmental) method for quantification of regional left ventricular dysfunction using gated myocardial perfusion SPET. Gated SPET is increasingly used to obtain complementary information on local perfusion and to assess the relevance of deficits in segmental count densities (attenuation vs perfusion deficit). The non-segmental approach was motivated by a hypothetical limitation regarding the validity of commonly used methods of quantitative wall thickening (WT) analysis. These methods are all based on segmental analysis, which could cause underestimation of 'true' contractile dysfunction in perfusion defects that do not have a strict segmental distribution. SPET images gated in eight time bins 60 min after the injection of 740 MBq 99Tcm-tetrofosmin or 99Tcm-sestamibi were recorded on a triple-headed camera in 20 normal subjects and in 16 patients within 2 weeks and again 3 months after myocardial infarction. Normal limits of wall thickening, calculated from pooled wall thickening profiles obtained in normal subjects, were used to identify and quantify areas with abnormal wall thickening in patients with coronary artery disease. The method was validated against data obtained from contrast ventriculography (CVG) and tested for reproducibility. The reproducibility of the method was excellent: r = 0.98 (WTsev measure 1 = 1.03WTsev measure 2 - 0.01). The localization of wall thickening abnormalities detected by gated SPET correlated well with the localization of regions with abnormal wall motion (WM) identified by CVG. The severity of the regional myocardial dysfunction assessed by gated SPET was closely correlated with the severity of the regional myocardial dysfunction derived from CVG: r = 0.85 (WMsev = 2.55WTsev + 2.30). Furthermore, a good correlation between the total wall thickening severity score and the global left ventricular ejection fraction (LVEF) was observed early and late after myocardial infarction: r = 0.80 (WTsev = -0.4LVEF + 0.46). We conclude that quantitative analysis of regional wall thickening assessed from gated SPET myocardial perfusion scintigraphy is a reliable parameter for regional ventricular function. Categorizing wall thickening abnormalities quantitatively may be helpful in assessing small changes in regional function that may occur between sequential gated SPET images.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Compostos Organofosforados , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Tecnécio Tc 99m Sestamibi
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...